Disassembly

To replace the PT100 B sensor you have to remove them from both the hot end and from the electronics at the bottom.

Important: Make sure filament is removed, the Ultimaker is turned off and power supply disconnected before you start the replacement.

Note: These instructions are the same for the Ultimaker 2 Go, Ultimaker 2 and Ultimaker 2 Extended.

1. Removing the bowden tube

  • Manually move the print head towards to center of the Ultimaker for easier access.
  • Remove the (blue or red) clamp clip.
  • Press down the tube coupling collet and pull the bowden tube out of the print head.

Img3378

2. Take the print head out of the Ultimaker

  • Tilt the sliding blocks on the left and right side of the X-axis of the print head a little bit so the X-axis gets loose.
  • Move the print head towards the front side and push on the Y-axis just behind the print head; now the Y-axis will get loose as well.
  • Take the print head and the two axes out of the Ultimaker.

Img4821

3. Loosening the print head housing

  • Put some tape (can be any tape) around the print head housing so it doesn’t fall apart later on.
  • Loosen the 4 thumbscrews that go from top to bottom through the print head. Now you will see 2 parts: the print head housing and the hot end part.

Img4826
Img4830

4. Disassembling the hot end

  • Remove the fan bracket; it’s attached with 2 screws on either side of the hot end.
  • Loosen the 2 screws that are in the top aluminum plate, after which you can take out the spring and PTFE coupler.

Img4831
Img4835

  • Loosen the nozzle from the hot end isolator (the metal part with the holes in it) by inserting a hex key in one of the holes of the hot end isolator and turning it counter clockwise. This way the nozzle will move down and loosen.

Img4842
  • Next, loosen the set screw that is attached to the top of the heater block and carefully pull out the PT100 B sensor* and heater cartridge.

*Important: Do not pull at the PT100 B sensor with much force, it can break. Take the PT100 B sensor cable out with a twisting motion, and apply some sewing machine oil or WD40 to the heater block if it feels stuck.

Img4845
Img4848

5. Electronics

  • Place the Ultimaker on its side and remove the electronics cover, which is attached to the bottom of the Ultimaker with two screws and hex nuts.

Img4886
Img4892

  • Unplug the PT100 sensor from “TEMP1” of the main board.

Img4896
Support